<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>19005</ErrorNumber>
<ErrorFamily>Power Distribution Board</ErrorFamily>
<ErrorMessage>
PDB: Drum Vacuum Drive Fault
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>ThermoFlex</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The drum vacuum inverter drive (Magnetek unit) has indicated a fault condition.
Please refer to the GPD 506 Technical Manual for fault types and troubleshooting
advice.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Reset machine.  Call Creo service.
</text></DescriptionText>
</OperatorAction>
<Cause>
Error seen by the Magnetek unit.  Check front LCD panel for error type (e.g. OL1).
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:49 2008 PST
</Updated>
<Links>
</Links>
</Error>